维普中文期刊产品整合服务
11篇 您的检索式:作者名="Fangjun Bao"
    题名 作者 年代 出处 被引量
1Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important?显示文摘Keratoconus is a bilateral,non-inflammatory,degenerative corneal disease.The occurrence and development of keratoconus is associated with corneal thinning and conical protrusion,which causes irregular astigmatism.With the disruption of the collagen organization,the cornea loses its shape and function resulting in progressive visual degradation.Currently,corneal topography is the most important tool for the diagnosis of keratoconus,which may lead to false negatives among the patient population in the subclinical phase.However,it is now hypothesised that biomechanical destabilisation of the cornea may take place ahead of the topographic evidence of keratoconus,hence possibly assisting with disease diagnosis and management.This article provides a review of the definition,diagnosis,and management strategies for keratoconus based on corneal biomechanics.FangJun Bao Brendan Geraghty QinMei Wang Ahmed Elsheikh 2016Eye and Vision2016,3,1:8
2Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness显示文摘Background:The eye globe exhibits significant regional variation of mechanical behaviour.The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions,and therefore suitable for determining the material properties of the complete outer ocular tunic.Methods:A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement;measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software;prevention of rigid-body motion and protection of the ocular surface from environmental drying.The method has been demonstrated on one human and one porcine eye globe,which were cyclically loaded.Finite element models based on specimen specific tomography,free from rotational symmetry,were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye’s outer tunic.Results:The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe.For the two eyes tested,the method showed a gradual change in the sclera’s stiffness from a maximum at the limbus to a minimum at the posterior pole,while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone.Further,for both the sclera and cornea,the load–displacement behaviour did not vary significantly between loading cycles.Conclusions:The first methodology capable of mechanically testing intact eye globes,with applied loads and boundary conditions that closely represent in vivo conditions is introduced.The method enables determination of the regional variation in mechanical behaviour across the ocular surface.Charles Whitford Akram Joda Steve Jones Fangjun Bao Paolo Rama Ahmed Elsheikh 2016Eye and Vision2016,3,1:2
3Fast segmentation of anterior segment optical coherence tomography images using graph cut显示文摘Background:Optical coherence tomography(OCT)is a non-invasive imaging system that can be used to obtain images of the anterior segment.Automatic segmentation of these images will enable them to be used to construct patient specific biomechanical models of the human eye.These models could be used to help with treatment planning and diagnosis of patients.Methods:A novel graph cut technique using regional and shape terms was developed.It was evaluated by segmenting 39 OCT images of the anterior segment.The results of this were compared with manual segmentation and a previously reported level set segmentation technique.Three different comparison techniques were used:Dice’s similarity coefficient(DSC),mean unsigned surface positioning error(MSPE),and 95%Hausdorff distance(HD).A paired t-test was used to compare the results of different segmentation techniques.Results:When comparison with manual segmentation was performed,a mean DSC value of 0.943±0.020 was achieved,outperforming other previously published techniques.A substantial reduction in processing time was also achieved using this method.Conclusions:We have developed a new segmentation technique that is both fast and accurate.This has the potential to be used to aid diagnostics and treatment planning.Dominic Williams Yalin Zheng Fangjun Bao Ahmed Elsheikh 2015Eye and Vision2015,2,1:2
4Trace water triggers high-efficiency photocatalytic hydrogen peroxide production显示文摘Photocatalytic production of hydrogen peroxide(H_(2)O_(2))has attracted much attentions as a promising method for sustainable solar fuel.Here,we demonstrate that trace water can drastically boost highefficiency photocatalytic production of H_(2)O_(2) with a record-high concentration of 113 mmol L^(-1) using alkali-assisted C_(3)N_(4) as photocatalyst in water/alcohol mixture solvents.By electron paramagnetic resonance(EPR)measurement,the radical species generated during the photocatalytic process of H_(2)O_(2) are identified.We propose alcohol is used to provide and stabilize-OOH radicals through hydrogen bond,while trace water could trigger photocatalytic production of H_(2)O_(2) via providing and transferring indispensable free protons to completely consume OOH radicals,which breaks the reaction balance of-OOH radical generation from alcohol.Thus-OOH radicals could be supplied by alcohol continuously to serve as a reservoir for high-efficiency production of H_(2)O_(2).These results pave the way towards photocatalytic method on semiconductor catalysts as an outstanding approach for production of hydrogen peroxide.Zaixiang Xu Yang Li Yongyong Cao Renfeng Du Zhikang Bao Shijie Zhang Fangjun Shao Wenkai Ji jun Yang Guilin Zhuang Shengwei Deng Zhongzhe Wei Zihao Yao Xing Zhong Jianguo Wang 2022Journal of Energy Chemistry2022,31,1:1
5Efficacy and Acceptability of Orthokeratology for Slowing Myopic Progression in Children: A Systematic Review and Meta-Analysis显示文摘Daizong Wen Jinhai Huang Hao Chen Fangjun Bao Giacomo Savini Antonio Calossi Haisi Chen Xuexi Li Qinmei Wang Antonio Queiros 2015Journal of Ophthalmology2015,,:1
6Effect of orthokeratology on precision and agreement assessment of a new sweptsource optical coherence tomography biometer显示文摘Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry(PCI).Methods:This study recruited fifty-one eyes of 51 normal children(8–16 years).An operator took measurements with the two biometers.Then,a second operator took measurements with the SS-OCT biometer.After orthokeratology was performed for one month,the same operators repeated the same procedures.Axial length(AL),mean keratometry(Km)at 2.5 mm and 3.0 mm diameters(Km2.5 and Km3.0),central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT)and corneal diameter(CD)were analyzed.Results:With the SS-OCT optical biometer,the test-retest repeatability of AL measurements was<0.06 mm.For all parameters,the coefficients of variation were<1.23%and the intraclass correlation coefficients were>0.95.The 95%limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm.After orthokeratology,the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology,while the absolute values of difference for AL,Km2.5,ACD and CD measurements were comparable.Conclusions:Before and after orthokeratology,the SS-OCT biometer showed high repeatability and reproducibility for all measurements.Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements.The CD measurement showed poor agreement between the two devices.Bao Shu Fangjun Bao Giacomo Savini Weicong Lu Ruixue Tu Haisi Chen Benhao Song Qinmei Wang Jinhai Huang 2020Eye and Vision2020,7,1:1
7Unintended changes in ocular biometric parameters during a 6-month follow-up period after FS-LASIK and SMILE显示文摘Background:Corneal refractive surgery has become reliable for correcting refractive errors,but it can induce unintended ocular changes that alter refractive outcomes.This study is to evaluate the unintended changes in ocular biometric parameters over a 6-month follow-up period after femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)and small incision lenticule extraction(SMILE).Methods:156 consecutive myopic patients scheduled for FS-LASIK and SMILE were included in this study.Central corneal thickness(CCT),mean curvature of the corneal posterior surface(K_(pm)),internal anterior chamber depth(IACD)and the length from corneal endothelium to retina(ER)were evaluated before and after surgery over a 6-month period.Results:Both the FS-LASIK and SMILE groups(closely matched at the pre-surgery stage)experienced flatter Kpm,shallower IACD and decreased ER 1 week post-surgery(P<0.01),and these changes were larger in FS-LASIK than in SMILE group.During the 1 week to 6 months follow up period,K_(pm),IACD and ER remained stable unlike CCT which increased significantly(P<0.05),more in the FS-LASIK group.Conclusions:During the follow up,the posterior corneal surface became flatter and shifted posteriorly,the anterior chamber depth and the length from the corneal endothelium to retina decreased significantly compared with the pre-surgery stage.These unintended changes in ocular biometric parameters were greater in patients undergoing FS-LASIK than SMILE.The changes present clear challenges for IOL power calculations and should be considered to avoid affecting the outcome of cataract surgery.Junjie Wang Bernardo T.Lopes Hechen Li Riccardo Vinciguerra Si Cao Songan Wu Rong Zhu Qinmei Wang Xiaobo Zheng Fangjun Bao Ahmed Elsheikh 2021Eye and Vision2021,8,1:1
8Review of in-vivo characterisation of corneal biomechanics显示文摘The study of corneal biomechanics in vivo has been evolving fast in recent years.While an organised corneal structure is necessary for its transparency,resistance to occasional external insults and bearing the intraocular pressure(IOP),which several clinically relevant events can disturb.This review focuses on three techniques that are available for clinical use,namely the Ocular Response Analyzer(Reichert Ophthalmic Instruments,Buffalo,NY,USA),the Corvis ST(Oculus Optikgerate GmbH,Wetzlar,Germany)and the Brillouin Optical Scattering System(Intelon Optics Inc.,Lexington,MA,USA).The principles and the main parameters of each device are discussed along with their strategies to improve accuracy in the IOP measurement,corneal ectasia diagnosis,evaluation of corneal cross-linking procedures,and planning of corneal refractive surgeries.Bernardo T.Lopes FangJun Bao JunJie Wang XiaoYu Liu LiZhen Wang Ahmed Abass Ashkan Eliasy Ahmed Elsheikh 2021Medicine in Novel Technology and Devices2021,,3:0
9Review of ex-vivo characterisation of corneal biomechanics显示文摘The evaluation of the corneal biomechanical behaviour has important clinical applications.To name a few,the accuracy of the intraocular pressure measurement,the study of corneal ectatic diseases and the assessment and optimisation of corneal surgical procedures are all highly influenced by corneal biomechanics.Over the last 45 years different ex-vivo methods were developed to study corneal biomechanical behaviour.Different tissue maintenance,support,loading systems,as well as different monitoring strategies of corneal deformations were employed.In this review,the most important and commonly used methods are outlined,including strip extensiometry,inflation,compression,indentation and tissue separation testing.Their particularities,applications,pros and cons and main applications are discussed.JunJie Wang XiaoYu Liu FangJun Bao Bernardo T.Lopes LiZhen Wang Ashkan Eliasy Ahmed Abass Ahmed Elsheikh 2021Medicine in Novel Technology and Devices2021,,3:0
10High intercorneal symmetry in corneal biomechanical metrics显示文摘Backgroud:To evaluate the symmetry of corneal biomechanical metrics,measured using an ocular response analyzer(ORA)and self-built corneal inflation test platform,in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure(IOPp).Methods:Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation.IOP was increased from 7.5 to 37.5 mmHg with 7.5 mmHg steps and biomechanical metrics were acquired using the ORA.At least 3 examinations were performed at each pressure stage.Two biomechanical metrics,corneal hysteresis(CH)and corneal resistance factor(CRF)were recorded and analyzed as a function of IOPp.Corneal specimens were then excised from the intact ocular globe and tested under inflation conditions up to 45.7 mmHg posterior pressure.The experimental pressure-deformation data was analyzed using an inverse modeling procedure to derive the stress-strain behavior of the cornea.Results:A comparison of corneal shape parameters showed no statistically significant difference(P>0.05)between bilateral eyes.Similarly,there were no statistically significant differences in values of CH,CRF and corneal stiffness(as measured by the tangent modulus,Et)between bilateral eyes(CH:F=0.94,P=0.54;CRF:F=4.42,P=0.35;Et:F=3.15,P=0.12)at different pressure levels.IOPp was highly correlated with CRF while the relationship with CH was less pronounced.Conclusions:An obvious interocular symmetry in biomechanical metrics is found in this research.IOP has been shown to have important influences on the value of CRF provided by ORA.XiaoBo Zheng FangJun Bao Brendan Geraghty JinHai Huang AYong Yu QinMei Wang 2016Eye and Vision2016,3,1:0
11Accuracy and reliability of orthogonal polynomials in representing corneal topography显示文摘Fitting of corneal topography data to analytical surfaces has been necessary in many clinical and experimental applications,yet absolute superiority of fitting methods was still unclear,and their overfitting risks were not well studied.This study aimed to evaluate the accuracy and reliability of orthogonal polynomials as fitting routines to represent corneal topography.Four orthogonal polynomials,namely,Zernike polynomials(ZPs),pseudo-Zernike polynomials(PZPs),Gaussian-Hermite polynomials(GHPs)and Orthogonal Fourier-Mellin polynomials(OFMPs),were employed to fit anterior and posterior corneal topographies collected from 200 healthy and 174 keratoconic eyes using Pentacam topographer.The fitting performance of these polynomials were compared,and the potential overfitting risks were assessed through a prediction exercise.The results showed that,except for low orders,the fitting performance differed little among polynomials with orders10 regarding surface reconstruction(RMSEs~0.3μm).Anterior surfaces of normal corneas were fitted more efficiently,followed by those of keratoconic corneas,then posterior corneal surfaces.The results,however,revealed an alarming fact that all polynomials tended to overfit the data beyond certain orders.GHPs,closely followed by ZPs,were the most robust in predicting unmeasured surface locations;while PZPs and especially OFMPs overfitted the surfaces drastically.Order 10 appeared to be optimum for corneal surfaces with 10-mm diameter,ensuring accurate reconstruction and avoiding overfitting.The optimum order however varied with topography diameters and data resolutions.The study concluded that continuing to use ZPs as fitting routine for most topography maps,or using GHPs instead,remains a good choice.Choosing polynomial orders close to the topography diameters(millimeters)is generally suggested to ensure both reconstruction accuracy and prediction reliability and avoid overfitting for both normal and complex(e.g.,keratoconic)corneal surfaces.Junjie Wang Xuefei Li Zheng Wang Pinakin G.Davey Yiyu Li Lanting Yang Mao Lin Xiaobo Zheng Fangjun Bao Ahmed Elsheikh 2022Medicine in Novel Technology and Devices2022,,3:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费