维普中文期刊产品整合服务
4篇 您的检索式:作者名="Halil AK"
    题名 作者 年代 出处 被引量
1Inexpensive and versatile method for trace Sn ( II ) and Sn ( IV ) ions in food sam- ples by CPE/FAAS显示文摘Songtll Ulusoy Halil Ibrahim Ulusoy Mehmet Ak ay 2012Food Chem2012,134,1:1
2Proton Magnetic Resonance Spectroscopy of the Hippocampus After Severe Traumatic Brain Injury显示文摘Ozlen F Sanus GZ Halil AK 2004Turkish Neurosurgery2004,14,34:1
3A novel indicator system for catalytic spectrophotometric determination and speciation of inorganic selenium species (Se(Ⅳ), Se(Ⅵ)) at trace levels in natural lake and river water samples显示文摘A novel catalytic kinetic method is proposed for the determination of Se(Ⅳ), Se(Ⅵ), and total inorganic selenium in water based on the catalytic effect of Se(Ⅳ) on the reduction of Celestine blue by sodium sulfide at pH 7.0 phosphate buffer. The fixed-time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the two calibration graphs are linear with a good correlation coefficient in the range 2-20 and 20-200 μg·L-1 of Se(Ⅳ) for the fixed-time method at 30℃. The experimental and theo- retical detection limits of the developed kinetic method were found to be 0.21 and 2.50 μg·L-1 for the fixed-time method (3 min). All of the variables that affect the sensitivity at 645 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se(Ⅳ) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus as long as chelating agents of thiourea and thiosulphate. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The relative standard deviations (RSDs) for ten replicate measurements of 2, 10, and 20 μg·L-1 of Se(Ⅳ) change between 0.35% and 5.58%, while the RSDs for ten replicate measurements of 3, 6, and 12 μg·L-1 of Se(Ⅵ) change between 0.49% and 1.61%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. The Se(Ⅳ), Se(Ⅵ), and total inorganic selenium in lake and river water samples have been successfully determined by this method after selective reduction of Se(Ⅵ) to Se(Ⅳ).Ramazan Gürkan Halil brahim Ulusoy Mehmet Akay Pinar Bulut 2011Rare Metals2011,30,5:1
4Inexpensive and versatile method for trace Sn(II) and Sn(IV) ions in food samples by CPE/FAAS显示文摘Songül Ulusoy Halil ?brahim Ulusoy Mehmet Ak?ay Ramazan Gürkan 2012Food Chemistry2012,,1:1
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费